Compressor City437-494-0964

Know the compressor.

Commercial refrigeration uses four main compressor families: semi-hermetic and hermetic reciprocating, scroll and screw. The model, the refrigerant and the electrical supply settle the match.

AI-generated illustration of a semi-hermetic compressor on a refrigeration rack with frosted suction piping
A semi-hermetic compressor on a rack, frost on the suction line. AI-generated illustration. Photo credits

Common compressor types.

FamilyBuiltCommon on
Semi-hermetic reciprocatingBolted construction that can be opened for service.Parallel racks and larger condensing units.
Hermetic reciprocatingSealed and compact.Smaller condensing units and self-contained equipment.
ScrollFew moving parts and smooth running.Condensing units and rack systems.
ScrewRotary compressors for the largest loads.Process refrigeration and industrial cold storage.

Before you order.

Confirm why the old compressor failed. Electrical faults, flooding and overheating can take out a replacement too, so the system should be checked before the new one goes in.

Electrical faults
The supply voltage and phase, and the contactor and protection that feed the compressor.
Flooding
Liquid refrigerant returning to the compressor: evaporator fans, the expansion valve and crankcase heat.
Overheating
Condenser airflow, the refrigerant charge and oil getting back to the compressor.

A qualified technician checks these on site. Tell us what they found.

Ask about a failure
AI-generated illustration of frost on an evaporator coil with copper return bends above a drain pan
Frost on an evaporator coil. AI-generated illustration.

Rebuilt, lifted, crated.

A rebuilt compressor beside the failed one. AI-generated illustration, shown with a slow camera move.
AI-generated illustration of a grey semi-hermetic compressor on a chain hoist above a pallet, a gloved hand holding a blank tag
A compressor lifted over a pallet, tag in hand. AI-generated illustration.
AI-generated illustration of four grey semi-hermetic compressors in open timber crates in a warehouse
Compressors crated for shipping. AI-generated illustration.

AI-generated illustrations of typical compressor work, not our premises or products. Photo credits.

What to send.

The five details to send
Full model and suffix; current refrigerant; voltage, phase and frequency; application; and clear nameplate and installation photographs.
Repair, rebuild or replacement
The right path depends on condition, damage, parts, system requirements and the agreed scope. A visual match does not establish interchangeability.
Service and recommissioning
The refrigeration system must be assessed and serviced by qualified personnel. Do not infer safe operating pressures or settings from an illustration or generic checklist.